Scope of use: Accumulation and storage of heated water.
Product material: Carbon steel.
Description: The tank is designed to accumulate heat from various sources, as well as to create multivalent heating systems (i.e. if you need joint operation of several heat sources, e.g. you want to combine a solid fuel and electric boiler, or a gas-fired and wood boiler, or a thermal pump and both solid fuel and electric boiler etc.). The SMART-TANK ZK series tank improves the heating system flexibility and acts as a hydraulic separator of the system circuits. It provides an excellent combination of the following heat sources:
Can be used with any heat source:
Gas-fired boiler
Solid fuel boiler
Pellet boiler
Electric boiler
Biomass boiler
Fireplace with a water jacket
Solar collector
The tank insulation is performed using NOFIRE technology with 70 mm thick, 100% recyclable polyester (which is an environmentally friendly material) with a high R-value and B-s2d0 high fire-resistance class in accordance with the European EN 13501 requirements
On the outside, the standard design tanks with a volume of up to and including 5000 l are protected by plastic covering.
Optional availability of tank modification according to a customer drawing (location of connection pipes, flanges, connection diameters, type and thickness of insulation), which is calculated individually.
1.The ZK series tank is designed for use in heating systems!
2. The heat storage tank is designed for operating temperatures ranging from +2 to +95 °C using water, aqueous-glycol solutions as well as alcohol ones.
3. All models in this series have the following design features:
A) The tanks are made of durable stainless steel and are designed for long-time running.
B) The lower support for the tank is based on the ring bearing principle, allowing the tank weight to be evenly distributed on the floor surface and ensuring stability.
C) All tanks are equipped with inlet and outlet fittings made from a seamless, thick-walled pipe.
Для полного просмотра таблицы характеристик листайте вправо-влево
Parameters | ZK – 300 | ZK – 500 | ZK – 750 | ZK – 1000 | ZK – 1200 | ZK – 1500 | ZK – 2000 | ZK – 3000 | ZK – 5000 | ||
Volume | liters | 295 | 485 | 703 | 995 | 1200 | 1525 | 2030 | 3540 | 4910 | |
Height | Н, mm | 1570 | 1605 | 1630 | 2205 | 2020 | 2370 | 2100 | 2260 | 3010 | |
Diameter | with insulation | mm | 630 | 780 | 920 | 920 | 1080 | 1080 | 1350 | 1630 | 1630 |
with insulation | mm | 500 | 650 | 790 | 790 | 940 | 940 | 1220 | 1500 | 1500 | |
Tank operating pressure | MPa | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | |
Maximum operating temperature | °C | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | |
Daily power loss | W | 240 | 400 | 560 | 810 | 970 | 1220 | 1620 | 2440 | 4070 | |
Mass | kg | 65 | 87 | 103 | 131 | 174 | 200 | 246 | 450 | 615 |
Technical Data Sheet
Download PDFProduct Catalog
Download PDFInstallation and operating instructions
Download PDF